Emerson Ovation 4D33816G04 Analog Input DCS Module
June 10, 2026

Emerson Ovation 4D33816G04 Analog Input DCS Module

Fully certified to NRC Class 1E nuclear safety standards, the 4D33816G04 is the fourth-generation top-tier fully optimized high-precision RTD temperature acquisition terminal daughter card, iteratively upgraded upon G01/G02/G03 generations for Emerson Westinghouse Common Q nuclear safety I&C platform. It samples ultra-stable temperature signals from 3-wire PT100 platinum resistance sensors deployed on reactor primary auxiliary pipelines, main rotating equipment bearings, containment accident cooling loops and nuclear safety critical process equipment, supplying high-accuracy temperature measurement data for safety monitoring, thermal trend tracking and reactor trip interlock logic.

Description

Parameter Specifications

  1. Part Number: 4D33816G04

  2. Manufacturer: Emerson Westinghouse

  3. Compatible System: Common Q Class 1E Safety Instrument & Control DCS System

  4. Matching Accessories: RTD temperature master acquisition boards, 49E-3649 rack backplane, 475HP1ENA9GMT redundant rack power supply

  5. PCB Material: Multi-layer ultra-thick copper zero-halogen V-0 flame-retardant high-Tg FR-4

  6. Dimension & Weight: 120mm × 66mm × 20.6mm; Net Weight: 60g

  7. Ambient Operating Envelope

    Operating Temperature: -30℃ ~ +75℃

    Storage Temperature: -50℃ ~ +130℃

    Humidity: 5%~98% RH, non-condensing

  8. Power Supply: DC 12V / DC 24V dual wide-range adaptive input

  9. Input Channels: 12 fully independent galvanic isolated RTD input channels

  10. Supported Sensor: 3-wire PT100 platinum resistance temperature detector

  11. Standard Measurement Range: -200℃ ~ +850℃

  12. Isolation Index

    Single channel 2200V AC isolation withstand; 2200V AC dielectric strength test for 60s; Insulation resistance ≥1500MΩ @500VDC

  13. EMC Anti-interference Performance

    Power frequency interference attenuation ≥55dB, fully compliant with IEC 61000-6-2 industrial EMC specification

  14. Protection & Intelligent Diagnosis Functions

    • Per-channel high-precision constant current limiting protection

    • Bidirectional ultra-high-energy surge absorption circuit

    • Reverse wiring polarity lockout protection

    • Microsecond-level real-time fault detection: RTD sensor open-circuit / short-circuit / three-wire breakage / poor contact fault

    • Nanosecond high-precision timestamp fault code real-time upload to master controller

    • Full capture of fault transient waveform + large-capacity permanent non-volatile historical fault storage

  15. Mechanical Reliability

    Continuous vibration resistance 12g (10–150Hz); Shock resistance 30g pulse, 11ms duration

  16. Core Feature: Single module hot swappable under energized rack without interrupting any safety temperature measurement loops

  17. Certifications: CE, UL508, IEC60204-1, NRC Class 1E nuclear safety qualification

  18. Aging Validation Standard: 96-hour full-load high-low temperature cyclic aging test + long-term thermal cycle fatigue durability verification

  19. Design Service Life: ≥150,000 hours of 24/7 unattended continuous operation

  20. Warranty Period: 12-month global unified warranty for original factory modules and certified factory refurbished modules

Application Fields

  1. Nuclear Power Plant Common Q Safety I&C Racks

    Ultra-high isolation high-precision temperature acquisition terminal for reactor auxiliary cabinets, covering primary cooling system pipelines, main pump/motor bearing and containment atmosphere PT100 temperature monitoring points.

  2. AP1000 Nuclear Post-Accident Monitoring System (PAMS)

    Top-tier anti-interference temperature signal conversion board for containment core accident cooling circuits, reactor vessel outer wall and containment vent pipeline PT100 temperature probes.

  3. Thermal & Hydropower Station Main Control Systems

    High-stability high-accuracy RTD input module for boiler drum wall, turbine/generator main bearing, stator winding and unit closed cooling water PT100 temperature detectors.

  4. High-Risk Explosion-Proof Petrochemical DCS Distributed Control System

    Premium nuclear safety grade temperature wiring terminal card for reactor inner wall, high-temperature reaction pipelines and storage tank bottom wall PT100 temperature sensors.

  5. Offshore Oil & Gas Explosion-Proof Automation Racks

    Anti-vibration ultra-stable isolation temperature acquisition interface for wellhead high-pressure crude pipelines, separator heating jackets and medium delivery pipelines PT100 probes.

  6. Large Diesel Generator Safety Sequential Control Cabinets

    High-precision temperature input subcard for engine cylinder liner, crankshaft main bearing and closed circulation cooling water PT100 temperature sensors.

  7. Municipal Large-Scale Water Treatment Safety Interlock DCS Systems

    High-performance isolation temperature measurement terminal for main sewage conveying pipelines, aeration tank walls and large blower motor bearing PT100 temperature detectors.

  8. Metallurgy & Cement Kiln Production Lines

    Heavy-duty high-temperature precision acquisition module for rotary kiln outer shell, high-temperature flue gas headers and raw material roasting conveying equipment PT100 temperature sensors.


Get a Quote