Description

EGE-ELEKTRONIK STS 212 S Air Flow Sensor Description

Overview

EGE-ELEKTRONIK STS 212 S is an intrinsically safe air flow sensor designed for gaseous media monitoring in hazardous explosion-proof areas. This air flow sensor adopts thermal measuring principle without moving mechanical parts, and the air flow sensor must be matched with a separate approved Ex evaluation amplifier for signal processing. The air flow sensor features G1/2 thread connection and 65mm insertion depth for direct installation into pipelines to monitor air flow velocity.

Features

EGE-ELEKTRONIK STS 212 S is built with corrosion-resistant 1.4571 stainless steel housing and carries ATEX certification for Zone 0, Zone 20 and separating wall Zone 0/1 hazardous locations. This air flow sensor has a measuring range of 2 to 25 m/s for air medium, supporting reliable flow detection for ventilation and purge gas circuits. The air flow sensor uses M12 plug connection for fast wiring and replacement, and the sensor itself contains no electronic evaluation circuit, which keeps the field side intrinsically safe. It has excellent pressure resistance up to 10 bar and stable performance under medium temperature up to 85°C. The air flow sensor can be installed via T-piece or welding socket, and it works with EGE SZAb series amplifiers to provide switch or analog output signals to the control system. It resists vibration and dust in industrial environments and is widely selected for safety interlock of gas and air pipelines.

Technical Parameters

EGE-ELEKTRONIK STS 212 S belongs to STS 212 series thermal flow sensor family, part number P11206. Measuring medium is air, flow detection range 2–25 m/s. Process connection is G1/2 male thread, insertion depth 65 mm. Material is stainless steel 1.4571. Protection rating IP67, ATEX approved for gas and dust hazardous zones. It is an intrinsically safe probe type sensor and requires an external certified Ex amplifier for power supply and signal conversion. The maximum medium temperature is 85°C, compressive strength 10 bar.

Working Principle

EGE-ELEKTRONIK STS 212 S receives intrinsically safe excitation power from the matched Ex amplifier. The air flow sensor heats the internal thermal element continuously. When air flows past the sensing tip, the airflow carries heat away and changes the temperature difference between the measuring element and reference element. The air flow sensor transfers this thermal variation signal to the evaluation amplifier. The amplifier converts the signal into standard switch or analog signal for the PLC. If airflow drops below the preset threshold, the amplifier triggers flow alarm or equipment interlock to protect fans, burners and process vessels from abnormal operation.

Application Fields

EGE-ELEKTRONIK STS 212 S is widely used in chemical plants, pharmaceutical production, paint booths and gas purge monitoring systems. It serves as flow supervision unit for explosion-proof air and gas pipeline circuits. This air flow sensor is a common spare replacement part for maintaining EGE hazardous area flow monitoring systems.


Get a Quote