Description

PR ELECTRONICS 4114 Universal Transmitter

Overview

PR ELECTRONICS 4114 (code 060096838) is a programmable universal transmitter from the PR 4000 series. It accepts multiple signal types including RTD, thermocouple, resistance, potentiometer, mA and voltage input, and converts them into standard 4–20mA or 0–10V analog output. It provides three-port galvanic isolation and supports SIL 2 safety applications. The optional removable display unit can be attached for on-site configuration and diagnostic readout. It is widely installed inside industrial control cabinets for temperature and resistance signal conditioning.

Features

This PR transmitter supports flexible input selection for temperature sensors and resistive devices. It delivers linearized conversion for RTD and thermocouple signals, and offers isolated power supply for two wire transmitters. The slim DIN rail housing saves panel space. The built-in diagnostic function detects sensor break and short-circuit faults, and triggers alarm signals to PLC and safety systems. It carries FM approval for Div 2 hazardous area installation and meets IEC 61508 SIL 2 safety standards. Parameter setup can be completed by the PR 4500 series display without opening the module housing.

Technical Parameters

Model: 4114 Order code: 060096838 Type: Universal signal transmitter Input types: RTD / TC / Ohm / Potentiometer / mA / Voltage Output: 4-20mA, 0-10V selectable Isolation: 3-port galvanic isolation Mounting: EN 50022 DIN rail Power supply: 21.6–253VAC / 19.2–300VDC Certification: FM, CE, SIL 2

Working Principle

Under normal operation, the 4114 samples the sensor signal continuously. It linearizes temperature signals from RTD or thermocouple and converts the measured value into a standard analog signal. The internal isolation barrier breaks ground loops between field sensors and control side. If sensor failure or out-of-range deviation is detected, the module outputs a fault signal to prompt maintenance.

Application Fields

This universal transmitter is widely used for temperature measurement, valve potentiometer signal conversion and instrument signal isolation in chemical plants, oil refineries, power plants and process control panels. It serves as a precision signal conditioning replacement spare part for PR electronics 4100 series systems.