ABB 2TLA020070R4600 PLUTO B20 v2 Safety Controller
Overview
ABB 2TLA020070R4600 PLUTO B20 v2 is a Jokab Safety programmable safety PLC, designed for machine safety control. It integrates Pluto safety bus interface and total 20 I/O points, directly connecting safety light curtains, emergency stop buttons, safety door switches and OSSD sensors. Multiple Pluto units can be linked on the safety bus to expand the safety system, and programming is completed via the Pluto Manager software with TÜV certified safety function blocks. This DIN rail safety controller is widely deployed inside automation control cabinets, available as new surplus, refurbished and tested replacement spare part for ABB Jokab safety systems.
Features
This safety controller supports Category 4 and Performance Level e (PL e) according to ISO 13849-1, with high diagnostic coverage for safety circuits. It has 8 failsafe inputs, 8 configurable non-failsafe outputs / secondary failsafe inputs, 2 independent failsafe relay outputs and 2 independent failsafe transistor outputs. The built-in Pluto safety bus allows networking up to 32 Pluto controllers in one safety system. The front LED indicators display input, output, bus and fault status for fast troubleshooting. It accepts 24VDC supply, adopts IP40 housing and IP20 terminal protection, and supports Modbus ASCII communication for data exchange with standard PLC and HMI. It can handle dynamic DYNlink safety signals and static safety contacts in one device.
Technical Parameters
Model: PLUTO B20 v2 Order code: 2TLA020070R4600 Type: Programmable safety controller / Safety PLC Supply voltage: 24 VDC Failsafe inputs: 8 Configurable I/O: 8 (non-failsafe output / failsafe input) Failsafe relay outputs: 2 Failsafe transistor outputs: 2 Safety rating: ISO 13849-1 Cat.4, PL e Communication: Pluto safety bus, Modbus ASCII Mounting: 35mm DIN rail Protection: IP40 housing, IP20 terminals
Working Principle
The PLUTO B20 v2 continuously monitors all connected safety devices. When emergency stop, safety gate open or light curtain interruption is detected, the safety controller immediately de-energizes the failsafe outputs to cut off power to hazardous machine actuators. The internal dual-channel safety logic conducts continuous self-check and cross-monitoring to avoid single fault disabling the protection function. Via the Pluto safety bus, safety signals are shared across networked Pluto stations for distributed machine safety control. Fault codes are stored and displayed for maintenance diagnosis.
Application Fields
This safety controller is widely used for robotic cells, packaging machines, woodworking equipment, metal cutting machinery and automated production line safety control panels. It serves as safety logic replacement spare part for ABB Jokab Pluto safety systems.