Yokogawa GCRV-GBARS88N0151/A036/B036 GC1000 Mark II Rotary Valve Description
Description
Yokogawa GCRV-GBARS88N0151/A036/B036 GC1000 Mark II Rotary Valve Description
Yokogawa GCRV-GBARS88N0151/A036/B036 is a high-precision rotary sampling valve, specially designed for Yokogawa GC1000 Mark II process gas chromatograph, used for sample gas switching, injection and column flow path switching control during chromatographic analysis. It features low dead volume structure, corrosion-resistant valve sealing assembly, precise stepping motor drive, stable repeatable switching action, matched with GC1000 chromatograph control unit for sampling sequence programming, switching time setting and valve leakage self-diagnosis. This GC rotary valve adopts compact mounting form inside the GC oven assembly, widely used for petrochemical gas composition online analysis cabinets. It delivers reliable sample gas flow path switching and injection control processing, stable chromatogram sampling timing control and valve leakage fault alarm judgment, and convenient valve replacement for Yokogawa GC1000 process gas chromatography analysis systems.
Features Yokogawa GCRV-GBARS88N0151/A036/B036 supports ultra-low dead volume sample switching, minimizes sample residue and cross-contamination, adapts to continuous online gas composition analysis under high-temperature oven environment. Galvanic isolation separates sample gas circuit from electrical drive and control circuit to suppress surge and electromagnetic interference, standard GC1000 oven layout supports quick inspection and maintenance. The valve maintains consistent sample gas flow path switching and injection control processing and accurate chromatogram sampling timing control and valve leakage fault alarm judgment under continuous analysis operation.
Technical Parameters Yokogawa GCRV-GBARS88N0151/A036/B036 complies with CE process analysis standards, supporting sustained sample gas flow path switching and injection control processing, real-time chromatogram sampling timing control and valve leakage fault alarm judgment and straightforward valve replacement during GC analyzer overhaul and commissioning.
Working Principle Process sample gas enters Yokogawa GCRV-GBARS88N0151/A036/B036 rotary valve. Stepping motor drives the rotor to rotate to switch the gas flow path, completes sample gas quantitative injection into chromatographic separation column according to analysis sequence; after switching, the valve continuously monitors internal sealing status and triggers fault alarm when leakage or drive abnormality occurs. When rotor sealing assembly, stepping motor or drive circuit ages and fails, technicians cut off instrument control power supply and carry out valve replacement to resume normal sample gas flow path switching and injection control processing and chromatogram sampling timing control and valve leakage fault alarm judgment.
Application Fields Yokogawa GCRV-GBARS88N0151/A036/B036 is widely used in refinery, natural gas station, petrochemical plant and chemical process online gas analysis cabinets. It undertakes sample switching and injection tasks for GC1000 Mark II gas chromatograph analysis systems. This Yokogawa GC rotary valve ensures dependable sample gas flow path switching and injection control processing, stable chromatogram sampling timing control and valve leakage fault alarm judgment and easy valve replacement for process analysis renovation and GC1000 spare part stocking projects.
Get a Quote