YOKOGAWA CENTUM A2NN30D-440000 Node Interface Unit Description
Description
YOKOGAWA CENTUM A2NN30D-440000 Node Interface Unit Description
Overview
The YOKOGAWA CENTUM A2NN30D-440000 is a robust node interface unit for the Yokogawa N-IO control system within CENTUM automation platform. This node interface unit delivers dual-redundant communication and dual-redundant power supply, and the node interface unit serves as the bridge between field control unit and distributed N-IO modules. It provides stable 24VDC power output for downstream I/O assemblies and supports optical ESB bus uplink for long-distance cabinet interconnection in process plants.
Features
The YOKOGAWA CENTUM A2NN30D-440000 supports reliable bus communication over ESB optical link and N-ESB local bus. The bus communication maintains data synchronization between FCU and remote I/O nodes, and the bus communication supports redundant path switching automatically to avoid single cable failure. It integrates built-in power supply circuitry to feed N-IO modules, with overvoltage, overcurrent and short-circuit protection. Front status LEDs display power, link and fault conditions for quick inspection. It adopts DIN rail mounting and meets G3 environmental coating option, resisting dust, humidity and corrosive atmosphere for petrochemical and power sites. Hot swap is supported for maintenance without interrupting the whole control network.
Technical Parameters
The YOKOGAWA CENTUM A2NN30D-440000 accepts 24VDC input and generates regulated 24VDC output for N-IO I/O units. The communication interface uses optical ESB bus with transmission distance up to 5km, compatible with 50Hz and 60Hz industrial systems. Its working temperature ranges from -40℃ to +70℃, non-condensing humidity 5% to 95%. It has high isolation strength between bus, power and field circuits and complies with industrial EMC standards. Diagnostic information can be read from the CENTUM HMI for event tracking and troubleshooting.
Working Principle
The YOKOGAWA CENTUM A2NN30D-440000 receives control commands from the FCU via optical ESB bus and distributes these orders to local N-IO modules through N-ESB bus. It also collects field I/O status and measurement data and uploads back to the controller. The whole distributed control loop relies on stable power distribution, and the power distribution supplies clean and protected DC power to connected I/O cards. Continuous power distribution ensures all I/O channels keep running steadily during normal operation and transient power disturbance.
Application Fields
The YOKOGAWA CENTUM A2NN30D-440000 is widely used in petrochemical, oil & gas, thermal power and pulp & paper industries. It is the core node adapter for CENTUM VP N-IO distributed control systems, used for remote I/O expansion and field cabinet integration.
Get a Quote