GE MULTILIN SR737 737-5-5-HL-485 Feeder Protection Relay Description
Description
GE MULTILIN SR737 737-5-5-HL-485 Feeder Protection Relay Description
Overview
The GE MULTILIN SR737 737-5-5-HL-485 is a microprocessor-based feeder protection relay for medium and low voltage distribution feeders. This feeder protection relay integrates phase and ground overcurrent protection functions, and the feeder protection relay supports front dial setting and RS485 communication for remote monitoring and event reading. It adopts panel mounting design and replaces multiple discrete overcurrent protection components in power distribution cabinets.
Features
The GE MULTILIN SR737 737-5-5-HL-485 provides configurable overcurrent protection including time overcurrent and instantaneous overcurrent for phase and ground fault. The overcurrent protection supports multiple selectable protection curves such as ANSI, IEC and IAC, and the overcurrent protection can be coordinated with upstream and downstream protection devices to narrow fault isolation range. It stores the latest trip records and shows fault cause through front panel indicators. The built-in RS485 interface supports Modbus communication for connection to SCADA systems. It has multiple relay output contacts for breaker tripping and alarm signaling, and the setting parameters can be adjusted directly via front dials without software.
Technical Parameters
The GE MULTILIN SR737 737-5-5-HL-485 accepts auxiliary power from 70-265VAC or 90-300VDC, compatible with 50Hz and 60Hz power systems. The CT secondary input is 5A for phase and ground circuits. Its working temperature ranges from -25℃ to +70℃, non-condensing humidity 5% to 95%. The communication port is two-wire RS485, and trip contacts and service contacts meet standard load capacity requirements. It complies with power industry protection standards for distribution network applications.
Working Principle
Current signals from current transformers are sent to the GE MULTILIN SR737 737-5-5-HL-485. The internal sampling circuit processes three-phase current and ground current data, then compares measured values against preset pickup thresholds and time curves. The whole protection response relies on accurate fault discrimination, and the fault discrimination identifies phase short circuit, phase overload and ground fault separately. Reliable fault discrimination triggers the trip contact quickly to open the circuit breaker and protect distribution cables and downstream loads.
Application Fields
The GE MULTILIN SR737 737-5-5-HL-485 is widely used in power plants, industrial factories, municipal power distribution and petrochemical facilities. It is applied for primary protection of distribution feeders, small transformers and motor feeder circuits.