Bently Nevada 330180-51-00 3300 XL 8mm Proximitor Sensor
May 23, 2026

Bently Nevada 330180-51-00 3300 XL 8mm Proximitor Sensor

DIN rail mount proximitor sensor for 5m 8mm eddy current probe system, measuring shaft vibration and displacement for industrial rotating machinery

Description

I. Model Decoding

330180: 3300 XL 8mm Eddy Current Preprocessor (50Ω system, API 670) 51

5: Total system length: 5m (probe + extension cable)

1: DIN rail installation (35mm standard rail)

00: Standard type, no explosion-proof / safety certification (for general areas) 


II. Technical Specifications (Electrical / Environmental / Mechanical)

Electrical Parameters

System Impedance: 50Ω (fully matched, cannot be mixed with 75Ω)

Power Supply Voltage: -17.5 ~ -26 VDC (typical - 24 VDC)

Operating Current: ≤ 12 mA

Sensitivity: 7.87 mV/μm (200 mV/mil)

Linear Range: 0.25 ~ 2.3 mm (10 ~ 90 mils)

Recommended Gap: 1.27 mm (50 mils, approximately - 9 VDC)

Frequency Response: 0 ~ 10 kHz (+0/-3 dB)

Output Signal: Negative DC Voltage (static displacement + dynamic vibration)

Signal Transmission Distance: Up to 305m from Preamplifier to Monitor

Environmental and Mechanical

Operating Temperature: -35°C ~ +85°C

Storage Temperature: -51°C ~ +100°C

Installation Method: 35mm DIN Rail Snap-In Installation (with electrical isolation included)

Dimensions: 81.3 × 35.1 × 63.5 mm

Weight: Approximately 0.25 kg

Shell: A308 Aluminum Alloy, Protection IP54

Certifications: CE, RoHS (No explosion-proof, No SIL)

III. Standard Accessories (5m System)

Probe: 330191-00-26-05-00 (8mm, 5m integrated cable, standard temperature)

Extension Cable: Not Required (5m integrated probe cable)

Monitor: 3500/40 (Vibration), 3500/42 (Axial Position)

IV. Installation and Wiring

1. Rail Installation

Align with 35mm DIN Rail, press down to secure; base comes with insulation, no additional insulation board required

2. Wiring Terminal (Standard)

-24 VDC (Power Negative)

COM (Common Port)

OUT (Signal Output)

SHIELD (Shielding Layer)

3. Gap Setting

Objective: 1.27 mm (-9 VDC)

Measure COM–OUT voltage with a multimeter, fine-tune the probe to the target and lock it

4. Cable and Shielding

Bend radius ≥ 25mm, do not cut

Shielding: Single-ended grounding at the cabinet end, floating at the probe end

V. Calibration (Periodic 12 Months)

Use standard gap blocks: 0.25/1.27/2.3 mm

Sensitivity Error: ≤ ±1%; Linear Deviation: ≤ ±0.31 mm

VI. Difference from 330180-51-05

330180-51-00: Standard Type, No Explosion-proof, for ordinary industrial environments

330180-51-05: With CSA/ATEX/IECEx Explosion-proof Certification, for Hazardous Areas


Get a Quote