NI PXI‑5600 2.7‑GHz PXI RF Down‑Converter
May 27, 2026

NI PXI‑5600 2.7‑GHz PXI RF Down‑Converter

一、产品简介 PXI‑5600是美国国家仪器(NI)推出的3U PXI 单槽宽带 RF 下变频器,为PXI‑5661 矢量信号分析仪(VSA)的核心射频前端模块,搭配PXI‑5142 IF 数字化仪组成完整 RF 分析系统。覆盖9 kHz–2.7 GHz,20 MHz 实时带宽,内置高稳定OCXO 时基,主打无线通信、雷达、电子战信号接收与下变频

Description

II. Model Interpretation

PXI: Standard 3U PXI bus, single slot, compatible with PXI/PXIe chassis.

5600: NI 5600 series RF downconverter model number:

56xx: RF/microwave instrument series;

xx00: Basic broadband downconverter (without integrated digital instrument).

Component number: 778283-01 (standard configuration, unique model).

Combination model: PXI-5600 + PXI-5142 = PXI-5661 VSA.

III. Technical Parameters (25℃, 50 Ω, typical values)

1. Frequency and Bandwidth

RF input frequency: 9 kHz – 2.7 GHz

Real-time bandwidth: 20 MHz (fixed IF bandwidth)

Output intermediate frequency (IF): 5 – 25 MHz

2. Input/Output Characteristics

RF input: SMA female, 50 Ω, AC coupling

Maximum input power: +30 dBm

Attenuation: 0 – 50 dB (10 dB step)

Noise density: < -135 dBm/Hz

IF output: SMA female, 50 Ω, 0 dBm full scale

3. Time Base and Stability

Reference source: Built-in 10 MHz OCXO (highly stable constant-temperature crystal oscillator)

Frequency stability: ±20 ppb (annual)

Frequency accuracy: ±50 ppb

Phase noise: < -94 dBc/Hz @ 10 kHz offset (1 GHz carrier)

4. Dynamic Range and Spurious

Spurious-free dynamic range (SFDR): > 80 dB

Third-order intermodulation: > 70 dBc

5. Physical and Environmental

Size: 3U single slot (approximately 160×100 mm)

Power consumption: approximately 18 W

Operating temperature: 0 – 55℃

Cooling: Forced air cooling (chassis fan)

IV. Interface and Communication Configuration

1. Front Panel (3×SMA)

RF IN (SMA): RF signal input, 50 Ω, AC coupling

IF OUT (SMA): Intermediate frequency output after downconversion, connected to PXI-5142's IF IN

REF IN (SMA): 10 MHz external reference input (-5 to +15 dBm), used for multi-card synchronization

2. Backplane and System Interface

PXI backplane: 32-bit PCI, PXI trigger bus (TRIG0–TRIG6), 10 MHz reference bus

Synchronization: Supports PXI trigger, NI-TClk multi-module phase synchronization

Driver: NI-RFSA (RF vector signal analysis driver), compatible with LabVIEW/TestStand/Python/C#

V. Core Functions

Broadband RF downconversion: 9 kHz – 2.7 GHz → 5 – 25 MHz IF, 20 MHz real-time bandwidth, covering mainstream wireless/radar frequency bands.

Highly stable OCXO time base: ±20 ppb stability, low phase noise, ensuring precise frequency and modulation measurement.

Large dynamic range: +30 dBm full scale, < -135 dBm/Hz noise density, > 80 dB SFDR, suitable for scenarios with both strong and weak signals.

Modular combination: Seamless integration with PXI-5142 (14-bit/100 MS/s digital instrument), quickly building PXI-5661 VSA.

Multi-card synchronization: Shared 10 MHz reference + NI-TClk, multi-module synchronization accuracy < 20 ps, supporting MIMO/multi-channel RF testing. VI. Application Scenarios

Wireless communication testing: 2G/3G/4G/5G (Sub-6G), WiFi, Bluetooth signal reception and demodulation, receiver sensitivity / anti-interference testing.

Radar / Electronic Warfare: Intermediate frequency acquisition in radar, pulse train / LFM signal analysis, electronic countermeasures (ECM) signal monitoring.

Aerospace / Defense: Low spurious RF reception, sensor simulation, military RF equipment calibration and verification.

Semiconductor testing: RF amplifier / filter / mixer performance verification, transceiver chip (SoC) modulation accuracy testing.

General RF R&D: Broadband signal capture, spectrum analysis, modulation quality (EVM / phase error) measurement.

VII. Usage and Maintenance Instructions

1. Installation and Power On

Power off installation, single slot fixed; chassis reliable grounding to prevent static electricity.

Power on preheating for 30 minutes (OCXO requires stable temperature), NI MAX self-check without hardware errors.

Keep ventilation during operation, temperature ≤ 55℃, avoid blocking the chassis fan.

2. Wiring and Operation

RF input uses 50 Ω high-precision SMA coaxial cable, tighten the connector, reduce standing wave.

Input power must not exceed + 30 dBm, otherwise burn the front end; strong signals (> 0 dBm) must be attenuated.

Multi-card synchronization: share 10 MHz reference (REF IN), enable NI-TClk, ensure phase coherence.

3. Calibration and Maintenance

Calibration cycle: recommended 1-year NIST traceable calibration; daily use internal self-calibration to compensate for temperature drift.

Interface maintenance: regularly clean SMA interface, keep dry; install dust cover for long-term inactivity.

Environmental requirements: no condensation, humidity 10%–90% RH; away from strong electromagnetic interference and vibration sources.

Prohibited operations: plug and unplug cables while powered on, overheating operation, interface overload, severe vibration.


Get a Quote