MOOG D661-4642 Electro-hydraulic Servo Valve
Description
Model Explanation (Basic Section)
D661: Series Code (Integrated Electronics, 24VDC, NG10)
4642: Valve Core / Valve Body Assembly, ServoJet® Pilot, Standard Flow / Pressure Rating
Technical Specifications
Hydraulic parameters
Rated flow rate: 75 L/min (ΔP = 35 bar)
Maximum working pressure: P/A/B ports 350 bar; internal leakage T port 210 bar, external leakage T port 350 bar (Moog Inc.)
Step response: 6.5–12 ms (0→100%, 210 bar)
Hysteresis: <0.2%; Resolution: <0.1%; Zero drift (ΔT = 55K): <1.5%
Zero position leakage: <15 mL/min
Electrical parameters
Power supply: 24 VDC (18–32 VDC) Moog Inc.
Control signal: ±10 V or ±10 mA Moog Inc.
Feedback signal: 4–20 mA (valve core position) Moog Inc.
Connection: 6+PE, protection IP65 Moog Inc.
Physical and environmental
Working temperature: -40℃ ~ +85℃
Weight: Approximately 5.5 kg
Interface and communication configuration
Hydraulic interface: P/A/B/T four ports, ISO 4401-05 standard
Electrical interface: power supply (24VDC/GND/PE), command (±10V/±10mA), feedback (4–20mA), status alarm Moog Inc. Core function
ServoJet® Jet Pipe Precedent: Strong anti-pollution performance, low drift, long service life. Moog Inc.
Integrated Closed-loop Amplifier: Built-in PID, hysteresis compensation, overload protection. Moog Inc.
Valve Core Position Electrical Feedback: Full travel high precision, high linearity. Moog Inc.
High Dynamic Response: Millisecond response, suitable for high-speed closed-loop control.
Application Scenarios
Metallurgy: Rolling mill AGC downstroke, tension control
Test Equipment: Vibration table, material testing machine, fatigue test bench
Industrial Automation: Precision machine tools, injection molding machines, hydraulic forming machines
Energy and Heavy Industry: Wind turbine pitch control, shield tunneling machine, ship rudder
Installation: Horizontal / Vertical installation, avoid strong vibration; Oil cleanliness NAS 1638-6 grade and above
Commissioning: 24VDC power supply, connect ±10V/±10mA instructions; Adjust zero point and gain through 4–20mA feedback
Maintenance: Regularly detect oil contamination degree; Calibrate zero point and gain every 6 months; Avoid long-term high-pressure standby without instructions
Get a Quote