MOOG D661-5625C Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
5625C = Spool/sleeve assembly; rated flow 60 L/min @ ΔP=35 bar (high‑linearity trim, standard response)
Typical full config example: G060KOAA5VSB0‑P
G060 = 60 L/min rated flow & standard response
KOAA = High‑linearity hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
5 = 5+PE connector, IP65
VSB0 = FKM seals, extended temp range, LVDT 4–20 mA feedback
P = High‑linearity ServoJet® pilot stage
Technical Specifications
Hydraulic Parameters
Rated flow: 60 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)
Step response: 10–13 ms (0→100%, 210 bar)
Hysteresis: <0.08%
Resolution: <0.04%
Null drift: <1.0% (ΔT=55 K)
Null leakage: <12 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)
Control signal: ±10 V (differential) or ±10 mA
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 5+PE, IP65
Current draw: ≤700 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 5.7 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
High‑Linearity ServoJet® Pilot: Optimized for 60 L/min, minimal hysteresis, superior linearity
Integrated Precision PID Amplifier: Onboard dead‑zone compensation, thermal/overload protection, stable null
LVDT Closed‑Loop Feedback: Excellent resolution and repeatability for critical motion control
Fail‑Safe Centering: Spool returns to neutral on power loss
60 L/min High‑Linearity Flow: Tuned for medium‑sized hydraulic systems requiring ultra‑precision
Application Scenarios
Industrial automation: Ultra‑precision CNC machine tools, high‑accuracy hydraulic presses, medical molding machines
Test equipment: High‑precision structural fatigue testers, vibration simulation tables, aerospace actuator test benches
Metallurgy: Precision tension control, high‑accuracy AGC roll gap control in light mills
Energy: Wind turbine pitch control (high‑precision units), marine precision auxiliary hydraulic systems
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibration/shock
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6
Commissioning: Apply 24 VDC; connect ±10 V/±10 mA command; calibrate zero/gain via 4–20 mA feedback
Maintenance: Check fluid contamination every 3 months; calibrate zero/gain every 6 months; avoid long idle periods at high pressure
Get a Quote