MOOG D661-6360 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
6360 = Spool/sleeve; rated flow 60 L/min @ ΔP=35 bar (high‑response linear trim, no LVDT, standard null)
Typical full config: G060HOGBENO9
G060 = 60 L/min & high frequency response
HOGB = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA, centered null
E = 6+PE connector, IP65
N = NBR seals, wide temp range
O9 = High‑response ServoJet® pilot
Technical Specifications
Hydraulic Parameters
Rated flow: 60 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 8–12 ms (0→100%, 210 bar)
Hysteresis: <0.10%
Resolution: <0.05%
Null drift: <1.5% (ΔT=55 K)
Null leakage: <12 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback: None (open‑loop)
Connector: 6+PE, IP65Moog Inc.
Current draw: ≤750 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 5.5 kg
Interface & Communication Configuration
Hydraulic: P/A/B/T, ISO 4401‑05 (NG10)
Electrical:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Status: Fault alarm output
Core Functions
High‑Response ServoJet® Pilot: Optimized for 60 L/min, fast response, good dirt tolerance
Integrated PID Amplifier: Dead‑zone compensation, thermal/overload protection, stable null
Open‑Loop Precision Control: High linearity/repeatability for cost‑effective motion control
Fail‑Safe Centering: Spool returns to neutral on power loss
60 L/min Balanced Flow: For medium‑to‑large systems needing speed and accuracy
Application Scenarios
Industrial automation: Large CNC, hydraulic presses, injection molding
Test equipment: Structural fatigue, vibration tables, actuator test benches
Metallurgy: Tension control, medium‑duty AGC roll gap control
Energy: Wind turbine pitch, marine auxiliary hydraulics
Usage & Maintenance
Installation: Horizontal/vertical; minimize vibration
Fluid: ISO VG46 mineral oil; maintain NAS 1638 Class 6 cleanliness
Commissioning: 24 VDC; ±10 V/±10 mA command; zero/gain calibration
Maintenance: Check contamination every 3 months; calibrate every 6 months; avoid long idle at high pressure
Get a Quote