MOOG D661-6393C Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated 24 VDC electronics, NG10 mounting)
6393C = Spool/sleeve assembly; rated flow 60 L/min @ ΔP=35 bar (high‑response linear trim, no LVDT, standard null, C‑code configuration)
Full model example: G60JOAA6VSM2HA
G60 = 60 L/min & high frequency response
JOAA = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA, centered null
6 = 6+PE connector, IP65
VSM2 = NBR seals, wide temp range, standard pilot
HA = Fail‑safe centering, no LVDT
Technical Specifications
Hydraulic Parameters
Rated flow: 60 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 8–12 ms (0→100%, 210 bar)
Hysteresis: <0.10%
Resolution: <0.05%
Null drift: <1.5% (ΔT=55 K)
Null leakage: <12 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback: None (open‑loop)
Connector: 6+PE, IP65Moog Inc.
Current draw: ≤750 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 5.5 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mAMoog Inc.
Status: Fault alarm output
Core Functions
High‑Response ServoJet® Pilot: Optimized for 60 L/min, fast response, excellent dirt tolerance
Integrated PID Amplifier: Dead‑zone compensation, thermal/overload protection, stable nullMoog Inc.
Open‑Loop Precision Control: High linearity and repeatability for cost‑effective motion control
Fail‑Safe Centering: Spool returns to neutral on power loss
60 L/min Balanced Flow: Ideal for medium‑sized systems requiring speed and accuracy
Application Scenarios
Industrial automation: Medium CNC machines, hydraulic presses, injection molding equipment
Test equipment: Structural fatigue testers, vibration tables, actuator test benches
Metallurgy: Tension control, medium‑duty AGC roll gap control
Energy: Wind turbine pitch control, marine auxiliary hydraulics
Usage & Maintenance
Installation: Horizontal/vertical mounting; minimize vibration
Fluid: ISO VG46 mineral oil; maintain NAS 1638 Class 6 cleanliness
Commissioning: Apply 24 VDC; connect ±10 V/±10 mA command; calibrate zero/gain
Maintenance: Check contamination every 3 months; calibrate every 6 months; avoid long idle periods at high pressure
Get a Quote