MOOG D661-8006 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated 24 VDC electronics, NG10 mounting)
8006 = Spool/sleeve assembly; rated flow 120 L/min @ ΔP=35 bar (high‑flow linear trim, no LVDT, standard null, 8006‑code configuration)
Typical full config example: G120HOAA6VSM2OA
G120 = 120 L/min rated flow & high flow capacity
HOAA = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
6 = 6+PE connector, IP65
VSM2 = NBR seals, wide temperature range, standard pilot
OA = Fail‑safe centering, no LVDT
Technical Specifications
Hydraulic Parameters
Rated flow: 120 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 10–14 ms (0→100%, 210 bar)
Hysteresis: <0.15%
Resolution: <0.05%
Null drift: <1.5% (ΔT=55 K)
Null leakage: <15 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15Moog Inc.
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback: No LVDT (open‑loop spool position control)
Connector: 6+PE, IP65Moog Inc.
Current draw: ≤700 mAMoog Inc.
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 5.7 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PEMoog Inc.
Command: ±10 V / ±10 mAMoog Inc.
Status: Fault alarm output
Core Functions
High‑Flow ServoJet® Pilot: Optimized for 120 L/min, fast dynamic response, excellent dirt toleranceMoog Inc.
Integrated PID Amplifier: Onboard dead‑zone compensation, thermal/overload protection, stable nullMoog Inc.
Open‑Loop Precision Control: High linearity and repeatability without LVDT feedback穆格中国
Fail‑Safe Centering: Spool returns to neutral on power lossMoog Inc.
120 L/min High‑Flow Dynamics: Tuned for systems requiring high flow and moderate response
Application Scenarios
Industrial automation: Large CNC machines, heavy‑duty hydraulic presses, large injection molding equipment
Test equipment: Large structural fatigue testers, high‑force vibration tables, large actuator test benches
Metallurgy: High‑force tension control, heavy‑duty AGC roll gap control
Energy: Large wind turbine pitch control, marine main hydraulics
Usage & Maintenance
Installation: Horizontal/vertical mounting; minimize vibration
Fluid: ISO VG46 mineral oil; maintain NAS 1638 Class 6 cleanlinessMoog Inc.
Commissioning: Apply 24 VDC; connect ±10 V/±10 mA command; calibrate zero/gain
Maintenance: Check contamination every 3 months; calibrate every 6 months; avoid long idle periods at high pressure