Bosch Rexroth DDS03.1-W030-DA02-00 Digital Servo Drive
Description
Model Definition
DDS03.1: Servo drive series 03.1 for DIAX02
W: Internal cabinet air cooling
030: 30 A peak current (10 A continuous)
DA02: Analog interface module (±10 V speed/torque command)
00: Software version (base firmware)
MPN: R911260126 (base unit) + DA02 module
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (from TVD/TVM power supplies)
Control power: 24 V DC (20–28 V DC)
Continuous output current: 10 A
Peak output current: 30 A (short-term)
Current loop cycle: 125 μs
Speed loop cycle: 500 μs
Position loop cycle: 2 ms
Power dissipation: Approx. 110 W
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD/MBW series
Mechanical & Environmental Parameters
Cooling method: Internal cabinet air cooling
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating at 55 °C)
Storage temperature: -30 °C to +85 °C
Max. altitude: 1000 m (35% derating at 5000 m)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: Approx. 5.5 kg
Interface and Communication Configuration
Feedback: Digital servo (resolver + digital encoder, standard)
System bus: 300 V DC shared bus for multi-axis systems
DA02 Analog Interface: ±10 V speed/torque command, ±10 V speed monitor output
Digital I/O: 6 inputs / 3 outputs (enable, fault, limit switches)
Expansion slots: U1–U2 (DA02 occupies one slot)
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
Current/speed/position three-loop control for high-precision motion
Internal air cooling saves cabinet space for dense layouts
Compact 60 mm width enables multi-axis integration
Digital feedback ensures high-resolution positioning and fast error detection
DA02 analog interface for direct connection to analog controllers/PLCs
Comprehensive protection: overvoltage, undervoltage, overcurrent, short circuit, overheating, feedback loss
Supports torque/speed/position control modes
Application Scenarios
CNC machine tools (mid-power axes with analog control)
Printing/textile/packaging machinery
Robotics/handling systems with 10 A continuous current
Retrofits of analog-controlled automation systems
Light-duty spindle drives
Usage and Maintenance
Install with cabinet airflow ≥ 100 m³/h to ensure proper cooling
Operate below 45 °C to avoid performance derating
Configure DA02 analog range (±10 V) and feedback type via IndraWorks
Clean internal air passages every 6 months to prevent dust buildup
Calibrate control loops and feedback system annually
Get a Quote