Bosch Rexroth DDS2.1-W100D-01 Digital Servo Drive
Description
Model Definition
DDS2.1: DDS02.1 series, compatible with DIAX02
W: Internal cabinet convection cooling
100: 100 A continuous, 200 A peak
D: Basic unit with digital servo feedback
01: Firmware version 01, factory default configuration
Technical Specifications
Electrical
DC bus: 300 V DC ±15% (from TVD/TVM power supply)
Control supply: 24 V DC (20–28 V DC)
Continuous current: 100 A
Peak current: 200 A (short‑term)
Current loop: 125 μs; Speed loop: 500 μs; Position loop: 2 ms
Power dissipation: ~450 W
Motor compatibility: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal convection (cabinet air circulation)
Protection: IP20 (front), IP10 (unit)
Operating temp: 0 °C to +45 °C (20% derate @55 °C)
Storage temp: -30 °C to +85 °C
Max altitude: 1000 m (35% derate above)
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~7.5 kg
Interface & Communication
Motor feedback: X4 dual‑channel (digital encoder/resolver)
System bus: Shared 300 V DC bus (multi‑axis parallel)
Communication: U1–U5 expansion slots (SERCOS/analog/fieldbus modules)
Digital I/O: 6 isolated inputs, 3 isolated outputs
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
Three‑loop control (current/speed/position) for high precision
Digital servo feedback for accurate positioning
Convection cooling for cabinet installation (no external fan)
Full protection: overvoltage/undervoltage/overcurrent/short‑circuit/overtemperature/feedback loss
Torque/speed/position control modes
Modular design for easy maintenance and expansion
Application Scenarios
Medium/heavy‑load CNC main axes
Large textile, printing, packaging machinery
Gantry systems, heavy conveying lines
DIAX02 system retrofits (100 A continuous)
Cabinet‑space‑constrained equipment without external cooling
Usage & Maintenance
Ensure cabinet airflow for heat dissipation
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/bus wiring before power‑on
Set parameters via IndraWorks (match motor/load)
Clean heat paths every 6 months; check terminals
Calibrate loops/feedback annually
Get a Quote