Bosch Rexroth DDS2.1-W150-DA01-0 Digital Servo Drive
Description
Model Definition
DDS2.1: DDS02.1 series, compatible with DIAX02 system
W: Internal cabinet convection cooling
150: 150 A continuous current, 300 A peak current
DA01: Digital servo feedback (DSF) + analog encoder emulation (DAE01.1)
0: 00 = standard version, no optional firmware module (FW)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM)
Control power: 24 V DC (20–28 V DC), 500 mA
Continuous output current: 150 A
Peak output current: 300 A (short‑term)
Current loop cycle: 125 μs
Speed loop cycle: 500 μs
Position loop cycle: 2 ms
Power dissipation: ~680 W
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD/LSF/ADF (digital encoders)
Mechanical & Environmental
Cooling: Internal cabinet convection (W)
Protection class: IP20 (front), IP10 (unit)
Operating temperature: 0 °C to +45 °C; 20% derating at 55 °C
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m; 35% derating above
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~8.0 kg
Interface & Communication
Motor feedback: X4 for DSF digital feedback + analog encoder emulation (DAE01.1)
System bus: Shared 300 V DC bus (multi‑axis parallel)
Communication: Slots for SERCOS, analog, or fieldbus modules
Digital I/O: 6 isolated inputs / 3 isolated outputs
Service port: RS232 (IndraWorks setup/diagnostics)
Expansion slots: U1–U5 for I/O/functional modules
Core Functions
Three‑loop control (current/speed/position) for high precision
DA01 dual interface: DSF + analog emulation for legacy compatibility
Internal convection cooling for standard cabinet installation
Comprehensive protection: over/undervoltage, overcurrent, short‑circuit, overtemperature, feedback loss
Control modes: torque/speed/position
Modular design for easy maintenance and expansion
Application Scenarios
Heavy‑load CNC main axes (mixed digital/analog systems)
Large textile, printing, packaging machinery with legacy analog controllers
Heavy‑duty gantries, conveyors, automated lines
DIAX02 retrofits requiring 150 A + digital/analog feedback
Cabinet‑space‑limited equipment without external cooling
Usage & Maintenance
Ensure unobstructed cabinet airflow for cooling
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/control wiring before power‑on
Set parameters via IndraWorks (motor/load‑specific)
Clean heat sinks/air passages every 6 months; inspect terminals
Calibrate loops/encoder signals annually