Bosch Rexroth DDS2.1-W150-DA02-01 Digital Servo Drive
Description
Model Definition
DDS2.1: DDS02.1 series, DIAX02-compatible
W: Internal cabinet convection cooling
150: 150 A continuous, 300 A peak current
DA02: Digital DSF feedback + advanced analog interface (DAA02.1) with absolute encoder emulation
01: Version 01 = firmware pre-installed, upgraded feature set
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (TVD/TVM-powered)
Control power: 24 V DC (20–28 V DC), 500 mA
Continuous output current: 150 A
Peak output current: 300 A (short-term)
Current loop: 125 μs;Speed loop: 500 μs;Position loop: 2 ms
Power dissipation: ~680 W
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD/LSF/ADF (digital/absolute encoders)
Mechanical & Environmental
Cooling: Internal convection (W)
Protection: IP20 (front), IP10 (unit)
Operating temp: 0 °C to +45 °C;20% derating @55 °C
Storage temp: -30 °C to +85 °C
Max altitude: 1000 m;35% derating above
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~8.0 kg
Interface & Communication
Motor feedback: X4 for DSF digital + absolute encoder emulation (DAA02.1)
System bus: 300 V DC shared bus (multi-axis)
Communication: 5 slots (U1–U5); DA02 = analog command module
Digital I/O: 6 isolated inputs / 3 isolated outputs
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
3-loop control (current/speed/position) for high precision
DA02 upgrade: Absolute encoder emulation + enhanced analog command (vs DA01 incremental-only)
Internal convection for standard cabinet installation
Full protection: Over/undervoltage, overcurrent, short-circuit, overtemperature, feedback loss
Control modes: Torque/speed/position;firmware-enabled advanced functions (v01)
Application Scenarios
Heavy-load CNC axes (mixed digital/analog with absolute feedback)
Textile/printing/packaging machinery with legacy analog controllers needing absolute position
Heavy gantries, conveyors, automated lines
DIAX02 retrofits requiring 150 A + absolute encoder emulation
Cabinet-space-limited equipment without external cooling
Usage & Maintenance
Ensure unobstructed cabinet airflow for cooling
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/control wiring before power-on
Configure via IndraWorks (motor/load-specific)
Clean heat sinks/air passages every 6 months;inspect terminals
Calibrate loops/encoder signals annually
Get a Quote