Bosch Rexroth DDS2.1-W200-D Digital Servo Drive
Description
Model Definition
DDS2.1: Servo drive series for DIAX02 systems (DDS02.1 is the full series designation)
W: Internal cabinet convection air cooling
200: 200 A continuous rated current, 400 A peak current
D: Digital servo motor feedback (default, no analog resolver support)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM power units)
Control power: 24 V DC (20–28 V DC operating range)
Continuous output current: 200 A
Peak output current: 400 A (short-term)
Current loop cycle: 125 μs
Speed loop cycle: 500 μs
Position loop cycle: 2 ms
Power dissipation: ~900 W
Compatible motors: MDD/MKD synchronous servos, LAR/LAF linear motors, 2AD series motors
Mechanical & Environmental
Cooling: Internal cabinet convection (no external fans)
Protection class: IP20 (front), IP10 (unit)
Operating temperature: 0 °C to +45 °C (20% derating at 55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~8.5 kg
Interface & Communication
Motor feedback: X4 dual-channel (digital encoder only, no resolver)
System bus: Shared 300 V DC bus (multi-axis parallel)
Communication: U1–U5 expansion slots (SERCOS, PROFIBUS, CANopen optional)
Digital I/O: 6 isolated inputs / 3 isolated outputs
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
Three-loop control (current/speed/position) for high precision
Digital feedback for enhanced noise immunity and stability
Internal convection cooling for cabinet installation flexibility
Comprehensive protection: overvoltage/undervoltage/overcurrent/short-circuit/overheating
Control modes: torque/speed/position (heavy-load optimized)
Modular design for easy maintenance and expansion
Application Scenarios
Ultra-heavy-load CNC main axes (multi-axis linkage)
Large textile/printing/packaging machinery (high sync precision)
Heavy gantry systems, large conveyors, automated lines
DIAX02 system retrofits (200 A continuous current requirement)
Cabinet-space-constrained equipment with no external cooling
Usage & Maintenance
Ensure unobstructed cabinet airflow for heat dissipation
Keep ambient temperature ≤45 °C to avoid performance loss
Complete power/feedback/bus wiring before power-on
Configure parameters via IndraWorks (match motor/load)
Clean heat sinks/air passages every 6 months; inspect terminals
Calibrate loops/feedback annually for long-term stability
Get a Quote