Bosch Rexroth DDS3.1-W050-D Digital Servo Drive
Description
Model Definition
DDS3.1: Third‑generation servo drive series for DIAX03 systems
W: Internal cabinet convection air cooling
050: 50 A continuous rated current, 100 A short‑term peak current
D: Digital servo feedback interface (e.g., EnDat, HiRes)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (supplied by TVD/TVM power units)
Control power: 24 V DC (20–28 V DC)
Continuous output current: 50 A
Peak output current: 100 A (short‑term)
Current loop cycle: 62.5 μs
Speed loop cycle: 250 μs
Position loop cycle: 1 ms
Power dissipation: ~750 W
Compatible motors: MDD/MKD synchronous servo motors, LAR/LAF linear motors, 2AD series
Mechanical & Environmental
Cooling: Internal cabinet convection
Protection class: IP20 (front), IP10 (unit)
Operating temperature: 0 °C to +45 °C; 20% derating at 55 °C
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m; 35% derating above 1000 m
Dimensions (W×H×D): 120 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 interface for digital servo signals (EnDat/HiRes)
System bus: 300 V DC shared bus for multi‑axis parallel connection
Communication: U1–U5 slots for optional SERCOS, PROFIBUS, CANopen modules
Digital I/O: 6 isolated inputs, 3 isolated outputs
Service port: RS232 (IndraWorks for setup/diagnostics)
Expansion: Empty slots for I/O and function modules
Core Functions
High‑speed three‑loop control for fast dynamic response
Digital feedback ensures high positioning accuracy and noise immunity
Internal convection cooling suits compact cabinet layouts (no extra cooling)
Comprehensive protection: overvoltage, undervoltage, overcurrent, short circuit, overheating, feedback loss
Supports torque/speed/position control modes for high‑load applications
Modular design simplifies maintenance and expansion
Application Scenarios
High‑load main axes of CNC machine tools and multi‑axis linkage
Heavy‑duty textile, printing, and packaging machinery
Automated assembly lines, material handling, and conveying equipment
DIAX03 system upgrades requiring digital feedback
Automation equipment with limited cabinet space and convection cooling
Usage and Maintenance
Ensure unobstructed cabinet airflow for effective heat dissipation
Keep ambient temperature ≤45 °C to avoid performance loss
Complete all power/feedback/bus/control wiring before power‑on
Set parameters and tune loops via IndraWorks based on operating conditions
Clean heat sinks and air passages, and check terminals every 6 months
Calibrate control loops and digital feedback signals annually