Bosch Rexroth DDS3.1-W150 Digital Servo Drive
Description
Model Definition
DDS3.1: Third-generation servo drive series matched with DIAX03 control system
W: Internal cabinet convection air cooling
150: 150 A continuous rated current, 300 A short-term peak current
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15%, supplied by TVD or TVM power units
Control power supply: 24 V DC, operating range from 20 V DC to 28 V DC
Continuous output current: 150 A
Peak output current: 300 A for short-time operation
Current loop cycle: 62.5 μs
Speed loop cycle: 250 μs
Position loop cycle: 1 ms
Power dissipation: Approximately 820 W
Compatible motors: MDD, MKD synchronous servo motors, LAR, LAF linear motors, 2AD series motors
Mechanical & Environmental Parameters
Cooling method: Internal cabinet convection air cooling
Protection class: IP20 for front panel, IP10 for the whole unit
Operating temperature: 0 °C to +45 °C, 20% performance derating at 55 °C
Storage temperature: -30 °C to +85 °C
Maximum installation altitude: 1000 m, 35% performance derating above 1000 m
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: Approximately 8.0 kg
Interface and Communication Configuration
Motor feedback: X4 dual-channel interface supporting digital encoder and resolver signals
System bus: Shared 300 V DC bus for multi-axis parallel connection
Communication: U1 to U5 expansion slots for optional SERCOS, PROFIBUS and CANopen modules
Digital I/O: 6 isolated inputs and 3 isolated outputs for basic control signals
Service port: RS232 interface for parameter setting and fault diagnosis via IndraWorks
Expansion slots: U1 to U5 reserved for additional I/O and functional modules
Core Functions
High-speed three-loop control delivers fast dynamic response and steady operation under heavy loads.
Dual feedback support adapts to different motor types and various industrial environments.
Internal convection cooling suits standard cabinet installation without extra cooling equipment.
Complete protection against overvoltage, undervoltage, overcurrent, short circuit, overheating and feedback signal loss.
Supports torque, speed and position control modes to meet heavy-load operation demands.
Modular design simplifies daily maintenance and functional expansion.
Application Scenarios
Heavy-load main axes and multi-axis linkage of CNC machine tools
Large textile, printing and packaging machinery
Heavy-duty gantry systems, large conveying equipment and automated production lines
DIAX03 system renovation and upgrade projects
Automation equipment with limited cabinet space and convection cooling design
Usage and Maintenance
Maintain unobstructed air circulation inside the cabinet to ensure effective heat dissipation.
Keep ambient temperature below 45 °C to prevent performance degradation.
Finish all wiring of power, feedback, bus and control circuits before powering on the device.
Set parameters and tune control loops via IndraWorks according to actual operating conditions.
Clean heat dissipation components and air passages, and inspect terminal connections every six months.
Calibrate control loops and feedback signals once a year to sustain long-term reliable operation.
Get a Quote