Bosch Rexroth DKC0.3-040-7-FM Servo Drive Controller
Description
Model Definition
DKC: Drive Controller (EcoDrive 03 series)
0.3: Platform revision (compatible with DKC02.3/DKC03.3 hardware)
040: Rated output current (40 A RMS)
7: Voltage class (700 V DC nominal bus)
FM: Factory-configured firmware (standard motion control)
Technical Specifications
Electrical Parameters
Input voltage: 3-phase 200–480 V AC, 50/60 Hz
Rated output current: 40 A (continuous), 80 A (peak, 2.5× overload)
DC bus nominal voltage: 700 V DC
Output voltage: Up to 800 V AC
Output frequency: 0–1000 Hz
Control supply: 24 V DC (±20%), 21 W power consumption
Short-circuit current rating: 42,000 A RMS
Mechanical & Environmental Parameters
Dimensions (W×H×D): 65 mm × 360 mm × 261 mm
Weight: Approximately 5.7 kg
Operating temperature: 0 °C to +45 °C (pollution degree 2)
Storage temperature: -30 °C to +85 °C
Protection class: IP20
Cooling: Internal blower (vertical mounting required)
Interface and Communication Configuration
Backplane: Internal system bus for power and logic exchange
Fieldbus: SERCOS (fiber-optic), PROFIBUS DP, CANopen (optional cards)
I/O: 24 V DC digital inputs/outputs (enable, fault, reference, limit switches)
Feedback: Incremental encoder (standard), absolute encoder (optional)
Diagnostics: 7-segment display, LED status indicators (power, run, fault)
Core Functions
Precision speed, position, and torque control for single-axis applications
2.5× overload capacity for dynamic acceleration/deceleration
Built-in motion profiles (point-to-point, jog, homing)
Comprehensive protection: overvoltage, undervoltage, overcurrent, overtemperature, short circuit
Real-time fault diagnosis with error code logging
Compatibility with Indramat MKD/MKE series servo motors
Application Scenarios
CNC machine tools (milling, turning, grinding)
Packaging, printing, and textile machinery
Automated assembly lines and material handling systems
Robotics and gantry systems requiring high precision
Retrofit projects replacing older DKC02.3/DKC03.3 drives
Usage and Maintenance
Install only in vertical orientation with minimum 80 mm bottom clearance and 150 mm top clearance for airflow
Verify input voltage matches drive rating before powering on
Wire motor and encoder cables per Rexroth guidelines (shielded, separated from power cables)
Check blower operation monthly; clean filters every 3–6 months in dusty environments
Inspect I/O terminal connections quarterly for tightness
Update firmware via SERCOS or RS232 using Rexroth IndraWorks software