Bosch Rexroth DKC01.1-040-7-FU Servo Drive
Description
Model Definition
DKC: Servo drive controller of ECODRIVE series
01.1: Hardware platform version
040: 40 A continuous rated output current
7: High voltage grade
FU: Special customized functional firmware
Technical Specifications
Electrical Parameters
Three-phase input voltage: 320 V AC to 480 V AC, 50/60 Hz
Continuous output current: 40 A
Peak output current: 80 A
Nominal DC bus voltage: 700 V DC
Control power supply: 24 V DC ±20%
Applicable motors: MKD, MKE series synchronous servo motors
Mechanical & Environmental Parameters
Cooling mode: Built-in forced air cooling
Dimensions (W×H×D): 65 mm × 350 mm × 250 mm
Weight: Approximately 5.2 kg
Operating temperature: 0 °C to +45 °C
Storage temperature: -30 °C to +85 °C
Protection class: IP20
Interface and Communication Configuration
Motor feedback: Supports incremental encoder and optional absolute encoder
Digital I/O: Integrated 24 V DC input and output terminals for enable, limit and fault signals
Control interface: Compatible with analog command and pulse command control
Communication: Optional expansion for fieldbus communication modules
Diagnostics: LED indicators and digital display for status and fault code
Core Functions
Supports torque, speed and position three standard control modes
Strong overload capacity to adapt to frequent acceleration and deceleration
Pre-installed FU customized firmware for specific motion requirements
Complete protection against overvoltage, undervoltage, overcurrent, overheating and short circuit
Supports homing, jog and fixed-point positioning functions
Compact structure for cabinet installation and layout
Application Scenarios
Main and auxiliary axes of high-power CNC machine tools
Heavy-duty packaging, printing and textile machinery
Automated production lines and large conveying equipment
Motion control equipment under 380V high-voltage power supply environment
Replacement and upgrading of old DKC01.1 series servo systems
Usage and Maintenance
Install the drive vertically and reserve enough space for ventilation and heat dissipation
Complete all power, motor and signal wiring before powering on the device
Use shielded cables for encoder and signal lines to reduce electromagnetic interference
Regularly clean cooling fans and dust filters every 3 to 6 months
Periodically check the tightness of terminals and the operating status of indicators
Complete parameter setting and debugging via dedicated configuration software
Get a Quote