Bosch Rexroth DKC01.3-100-7-FW Servo Drive
Description
Model Definition
DKC: ECODRIVE series drive controller
01.3: Hardware platform (Type 3, modular I/O)
100: Rated continuous output current (100 A RMS)
7: High voltage class (700 V DC nominal bus, 380–480 V AC input)
FW: Firmware-version unit (application firmware ordered separately)
Technical Specifications
Electrical Parameters
Input voltage: 3-phase 380–480 V AC, 50/60 Hz
Continuous output current: 100 A
Peak output current: 200 A (2× overload capacity)
DC bus nominal voltage: 700 V DC
Control supply: 24 V DC ±20%
Compatible motors: MKD/MSK/MHD series high-power servo motors (15–22 kW)
Max output frequency: 1000 Hz
Mechanical & Environmental Parameters
Dimensions (W×H×D): 210 mm × 360 mm × 32.5 mm
Weight: Approx. 4.4 kg
Operating temperature: 0 °C to +45 °C
Storage temperature: -25 °C to +80 °C
Protection class: IP20
Cooling: Internal forced-air cooling (vertical mounting required)
Interface and Communication Configuration
Motor feedback: Incremental encoder (standard); absolute encoder (optional)
Digital I/O: 24 V DC inputs/outputs (enable, fault, limit, reference)
Control interfaces: Analog (±10 V) / pulse command (standard)
Communication: RS232/485 (standard); PROFIBUS DP, CANopen (optional cards)
Diagnostics: 7-segment display + LED status indicators
Core Functions
Torque, speed, and position control modes
2× overload capacity for heavy-load dynamic acceleration/deceleration
FW firmware structure (requires separate application firmware/ESM module)
Built-in homing, jog, and point-to-point positioning
Comprehensive protection: overvoltage, undervoltage, overcurrent, overtemperature, short circuit
Regenerative power capability (supports external braking resistors)
Application Scenarios
High-power CNC machine tools (main/spindle axes)
Heavy-duty packaging, printing, and textile machinery
Automated assembly lines with high payloads
Material handling systems (conveyors, cranes, hoists)
380–480 V AC industrial automation environments
Retrofit of legacy Indramat DKC01.3 high-voltage systems
Usage and Maintenance
Mount vertically with sufficient top/bottom clearance for airflow
Verify input voltage matches 380–480 V AC rating before power-on
Use shielded cables for motor/encoder wiring; separate from power cables
Clean cooling fans/filters every 3–6 months (dusty environments)
Check terminal connections quarterly for tightness
Commission via IndraWorks/DriveTop software with specified FW firmware
Get a Quote