JANCD-CU05
Description
General Description
Specifications
Manufacturer: Yaskawa Electric (Yasnac / Motoman)
Model: JANCD-CU05
Type: Auxiliary Control Board / Interface Terminal Board
Compatible Systems: Motoman XRC robot controllers; YASNAC LX1 / LX3 CNC systems
Power Supply: 24 V DC ±10%
Typical Current Draw: ~450 mA
Operating Temperature: 0 °C to +55 °C
Storage Temperature: -20 °C to +85 °C
Protection: Overvoltage, overcurrent, surge, and ESD protection
Weight: Approx. 1.0 kg
Status: Discontinued, sold as spare parts only
Key Features
Signal Conversion & Isolation: Translates and isolates I/O signals between the controller and external devices, reducing electrical interference.
Power Monitoring & Distribution: Monitors 24 V DC supply and distributes power to on-board and external I/O modules.
LED Status Indicators: On-board LEDs show power and signal activity for quick diagnostics.
Rack-Mount Design: Standard slot mounting for easy installation and direct replacement in XRC/LX cabinets.
Industrial-Grade Reliability: Coated PCB and rugged components ensure long-term stability in factory conditions.
Applications
Motoman XRC Robot Controllers: Used in automated welding, material handling, assembly, and palletizing lines.
YASNAC LX CNC Systems: Applied to lathes, machining centers, and other machine tools.
Legacy Equipment Maintenance: Common replacement part for aging Yaskawa automation systems.
Compatibility Notes
Model Specificity: Designed exclusively for XRC robot and LX CNC platforms; not interchangeable with CU01, CU03, CU04, or other CU-series boards.
Revision Matching: Verify part number, hardware revision, and compatibility with the main CPU board before replacement.
For Maintenance Only: Not recommended for new system builds; intended solely for servicing existing legacy equipment.
Installation & Maintenance
Install in a clean, dry, ventilated cabinet away from corrosive gases, heavy dust, and liquids.
Firmly insert into the designated rack slot; ensure all connectors and terminals are fully seated and locked.
Confirm 24 V DC input is within rated range before powering on.
Periodically inspect the board, connectors, and wiring for dust, oxidation, or loose connections.
Do not modify circuits or connect loads beyond rated specifications; use only original or fully compatible spare parts.
Get a Quote