Reliance Electric 45C-766(45C766)8‑channel isolated relay output module
May 30, 2026

Reliance Electric 45C-766(45C766)8‑channel isolated relay output module

The Reliance Electric 45C-766 (also written as 45C766) is an 8‑channel isolated relay output module for the Shark XL and AutoMax/AutoMate control platforms. Manufactured by Reliance Electric and also rebranded by Horner Electric as 45CRLY / HE45C‑RLY, it provides eight individually isolated, high‑current relay contacts for switching AC/DC loads in industrial automation. It features a compact DIN‑rail form factor, front‑panel terminal strip, onboard fuses and LED diagnostics, built for reliable long‑term operation in harsh factory environments.

Description

Product Introduction

The Reliance Electric 45C-766 (also written as 45C766) is an 8‑channel isolated relay output module for the Shark XL and AutoMax/AutoMate control platforms. Manufactured by Reliance Electric and also rebranded by Horner Electric as 45CRLY / HE45C‑RLY, it provides eight individually isolated, high‑current relay contacts for switching AC/DC loads in industrial automation. It features a compact DIN‑rail form factor, front‑panel terminal strip, onboard fuses and LED diagnostics, built for reliable long‑term operation in harsh factory environments.

Model Interpretation

  • 45C = Family code for Reliance Electric AutoMax/AutoMate/Shark XL series I/O modules.

  • 766 = 8‑channel isolated relay output module; “7” denotes high‑current isolated relay, “66” relates to output configuration.

  • (‑) = Common separator in ordering; functionally identical to 45C766.

  • Alternate 45CRLY / HE45C‑RLY = Horner Electric equivalent part number.

Technical Parameters

  • Outputs: 8 independent, electrically isolated normally open (N.O.) relay channels.

  • Rated voltage: 250 VAC, 125/250 VDC.

  • Rated current: 10 A per channel resistive (AC), 5 A per channel (DC).

  • Min switching load: 100 mA @ 5 VDC.

  • Isolation: 2,500 Vrms between channels and logic; channel‑to‑channel isolation.

  • Fuses: Individual replaceable fuses per channel (AGC type, 5 A / 250 V).

  • Indicators: Power LED, 8 channel ON LEDs, 8 fuse‑fault LEDs on front panel.

  • Operating temperature: ‑20 °C to +60 °C.

  • Protection class: IP20 (cabinet use).

  • Mounting: 45C‑series DIN rail.

  • Terminals: 18‑position screw terminal strip (two rows of nine).

  • Certification: CE, UL listed for industrial control.

  • Mechanical life: >100,000 operations per relay.

Interface and Communication Configuration

  • Backplane connection: Plug‑in to Shark XL / AutoMax backplane for power and logic I/O.

  • Field wiring: Front‑panel 18‑position screw terminals for eight relay common and normally open contacts.

  • Communication: Backplane bus only; no external serial/network ports.

  • Compatibility: Shark XL, AutoMax, AutoMate PLC systems; 45C‑series I/O rail (up to 8 modules per rail).

Core Functions

  • Converts controller logic signals into 8‑channel isolated relay switching for high‑current loads.

  • Provides galvanic isolation between control system and field devices to suppress noise and protect circuitry.

  • Individual channel fuses offer overcurrent protection per output.

  • LED status enables real‑time diagnostics for power, channel state, and fuse faults.

  • Hot‑swap capable (with system power removed) for easy replacement.

Application Scenarios

  • Industrial automation: Driving contactors, motor starters, solenoid valves, heaters, and large indicator lamps.

  • Process control: 120/230 VAC or 24/48/110 VDC high‑current switching on production lines, machine tools, packaging, and material handling equipment.

  • Panel‑building: Isolated, multi‑channel output for OEM panels requiring robust load driving and safety isolation.

Operation and Maintenance Instructions

  • Install on a 45C‑series DIN rail and ensure full backplane engagement before powering on.

  • Torque all field wiring terminals to manufacturer specifications; verify insulation integrity.

  • During operation, monitor front‑panel LEDs: power ON, channel LEDs follow command state, fuse LEDs OFF for normal operation.

  • If a fuse LED illuminates, power down the system, replace the corresponding AGC 5 A / 250 V fuse, and inspect wiring for shorts.

  • Keep the module surface clean and free of dust to maintain proper heat dissipation.

  • Disconnect system power before removal, inspection, or replacement.

  • Do not disassemble internal components; replace the entire module if a permanent fault occurs.

  • The unit is discontinued by Reliance Electric; use surplus or refurbished units for replacement.


Get a Quote