45C = Family code for Reliance Electric Shark XL series I/O modules.
994 = Analog output module; “9” = special function I/O, “94” = 2‑channel, 0–10 VDC output type.
No suffix = standard revision; compatible with all Shark XL racks.
Technical Parameters
Channels: 2 single‑ended analog outputs.
Output range: 0–10 VDC (voltage only).
Resolution: 8 bits (256 steps, ~39 mV per step).
Output impedance: 100 Ω per channel.
Conversion time: 1 ms per channel.
Isolation: No galvanic isolation between field and logic; no channel‑to‑channel isolation.
Indicators: Power OK LED, module fault LED.
Operating temperature: ‑20 °C to +60 °C.
Storage temperature: ‑40 °C to +85 °C.
Humidity: 0–95% RH, non‑condensing.
Protection class: IP20 (cabinet mounting).
Mounting: Shark XL / 45C‑series DIN rail.
Certification: UL, CE, CSA.
Power consumption: ~25 mA @ 5 VDC (backplane).
Interface and Communication Configuration
Backplane connection: Plug‑in to Shark XL rack backplane for power and data exchange.
Field wiring: Front‑panel screw terminals for 2 analog outputs (0–10 VDC) and common ground.
Communication: Backplane bus only; no external serial/network ports.
Compatibility: Shark XL PLC systems; 45C‑series I/O rail (up to 8 modules per rail).
Core Functions
Converts PLC digital values to 0–10 VDC analog signals for proportional control.
2‑channel independent output for dual‑actuator applications.
Fast 1 ms conversion time for real‑time control response.
LED status enables quick verification of power and module health.
Compact design integrates seamlessly with Shark XL racks for centralized I/O control.
Application Scenarios
Process control: Driving proportional valves, motor speed controllers, and analog displays.
Manufacturing: Controlling actuators in assembly lines, packaging, and material handling.
HVAC: Adjusting dampers and valves in building automation systems.
Water/wastewater: Regulating flow and pressure via analog control signals.
Operation and Maintenance Instructions
Install on a Shark XL DIN rail and ensure full backplane engagement before powering on.
Wire 0–10 VDC analog outputs to front‑panel terminals; observe polarity and common ground.
Verify load impedance is ≥ 1 kΩ to prevent output overload.
During operation, monitor LEDs: Power OK ON, fault LED OFF for normal status.
Keep the module clean and well‑ventilated to prevent overheating.
Disconnect system power before removal, inspection, or replacement.
Do not disassemble internal components; replace the entire module if a permanent fault occurs.
The unit is discontinued by Reliance Electric; use surplus or refurbished units for replacement.