ABB Sace Emax2 E4.2 Low Voltage Air Circuit Breaker Description
Description
ABB Sace Emax2 E4.2 Low Voltage Air Circuit Breaker Description
ABB Sace Emax2 E4.2 is a frame size E4.2 air circuit breaker from ABB Emax2 series low voltage ACB, max rated uninterrupted current up to 4000A, supports fixed and withdrawable version, equipped with Ekip electronic trip unit for LSIG/LSI protection, embedded energy metering, fault recording and ABB Ability cloud connection function, compatible with main distribution switchgear for industrial and critical power supply. It delivers reliable power circuit on-off and short-circuit fault interruption, stable low voltage main distribution protection control and convenient circuit breaker replacement for high-capacity power distribution systems.
Features ABB Sace Emax2 E4.2 air circuit breaker adopts modular pole construction, high breaking performance and full selectivity protection, supports 3-pole / 4-pole configuration. Ekip trip unit offers Class 1 power measurement accuracy, comprehensive protection includes overload, short-circuit, earth fault, overvoltage and undervoltage protection, touch screen interface supports parameter setting and fault diagnostics. Galvanic isolation separates high-current primary circuit from low-voltage control circuit to suppress surge and transient interference, withdrawable chassis allows safe rack-in / rack-out operation without de-energizing upstream busbar, built-in mechanical interlock prevents misoperation. The breaker maintains consistent power circuit on-off and short-circuit fault interruption and accurate low voltage main distribution protection control under long-cycle continuous operation.
Technical Parameters ABB Sace Emax2 E4.2 ACB rated operational voltage up to 690VAC, complies with IEC60947-2, IEC61557-12 and CE power distribution standards, supporting sustained power circuit on-off and short-circuit fault interruption, real-time low voltage main distribution protection control and straightforward circuit breaker replacement during switchgear overhaul and commissioning.
Working Principle Closing command energizes the operating mechanism of ABB Sace Emax2 E4.2 air circuit breaker. The stored energy mechanism closes main contacts for normal power transmission. When overload or short-circuit fault current occurs, Ekip trip unit sends trip signal instantly to release the contact mechanism and cut off fault circuit rapidly, isolating downstream loads from the fault source. When contact assembly, trip unit or operating mechanism aging and failure occurs, technicians isolate the switchgear and carry out circuit breaker replacement to resume normal power circuit on-off and short-circuit fault interruption and low voltage main distribution protection control.
Application Fields ABB Sace Emax2 E4.2 is widely used in data center, power plant, petrochemical plant, mining, water treatment skid and commercial building main distribution switchgear panels. It undertakes incoming feeder protection and power distribution control tasks for large-capacity low voltage power systems. This ABB Emax2 E4.2 air circuit breaker ensures dependable power circuit on-off and short-circuit fault interruption, stable low voltage main distribution protection control and easy circuit breaker replacement for power distribution renovation and high-current ACB spare part stocking projects.