ABB SACE TMAX XT4N Molded Case Circuit Breaker Description
November 25, 2026

ABB SACE TMAX XT4N Molded Case Circuit Breaker Description

The ABB SACE TMAX XT4N is a molded case circuit breaker for power distribution and motor protection. This molded case circuit breaker belongs to the Tmax XT series, supporting thermal magnetic and electronic trip units, and the molded case circuit breaker offers adjustable overload, short circuit and ground fault protection schemes. It has high breaking capacity and optional Ekip electronic trip unit with measuring and communication function, supporting fixed, plug-in and withdrawable mounting styles for MCC and switchgear cabinet retrofit.

Description

ABB SACE TMAX XT4N Molded Case Circuit Breaker Description

The ABB SACE TMAX XT4N is a molded case circuit breaker for power distribution and motor protection. This molded case circuit breaker belongs to the Tmax XT series, supporting thermal magnetic and electronic trip units, and the molded case circuit breaker offers adjustable overload, short circuit and ground fault protection schemes. It has high breaking capacity and optional Ekip electronic trip unit with measuring and communication function, supporting fixed, plug-in and withdrawable mounting styles for MCC and switchgear cabinet retrofit.

Features The ABB SACE TMAX XT4N provides reliable current protection for distribution and motor feeders. The current protection supports TMD thermal magnetic release and Ekip LSIG electronic release versions, and the current protection carries adjustable long time overload, short time short circuit and instantaneous fault tripping functions. It supports optional earth fault protection and neutral pole protection for four pole schemes. The front handle provides manual close and trip operation, and the optional Ekip touch display unit shows measured current, thermal state and fault code. It supports auxiliary contact and alarm contact signal output for PLC and SCADA system remote monitoring. The breaking capacity of N version reaches 36kA at 415V AC, and it complies with IEC 60947-2 standard. The modular accessory design includes shunt trip, undervoltage release and motor operator for automatic control layout. The coated casing and internal busbar structure adapts to dust and vibration environments inside low voltage electrical cabinets.

Technical Parameters The ABB SACE TMAX XT4N adapts to three-phase AC power supply up to 690V, frame current up to 250A, compatible with 50Hz and 60Hz power grids. Its working temperature ranges from -25℃ to +70℃, non-condensing humidity 5% to 95%. It supports terminal front connection and rear connection wiring options, and the hot swap capable structure meets maintenance replacement requirements. The built-in memory stores fault trip event logs and operation statistics data for troubleshooting and analysis. It supports standard panel cutout dimension to replace old Tmax XT series breakers directly.

Working Principle Three-phase load current passes through the primary busbar of the ABB SACE TMAX XT4N. The built-in current transformer samples current signal and sends to the trip unit. The whole protection loop relies on fast fault triggering, and the fault triggering cuts off the power supply once overload or short circuit condition is confirmed. Reliable fault triggering protects distribution cable, motor and downstream equipment from severe damage.

Application Fields The ABB SACE TMAX XT4N is widely used in power plants, water treatment, petrochemical and industrial distribution systems. It is applied for main feeder protection, motor control center and low voltage switchgear outgoing circuit protection.


Get a Quote