ABB SACE EMAX2 E1.2B Air Circuit Breaker Description
Description
ABB SACE EMAX2 E1.2B Air Circuit Breaker Description
ABB SACE EMAX2 E1.2B is a 3-pole intelligent air circuit breaker, rated uninterrupted current 630A, rated operational voltage 690V AC, rated impulse withstand voltage 12kV, applicable AC frequency 50/60Hz, equipped with Ekip solid-state trip unit, integrates overload, short-circuit and earth fault protection function, supports Modbus and IEC61850 communication, Ekip touchscreen for protection setting, power metering, fault waveform capture and breaker status feedback, available in fixed or withdrawable mounting version, built-in auxiliary contact for breaker position feedback and interlock control. This ACB power circuit breaker adopts low loss contact system, meets IEC60947-2 standard, widely used for main incoming feeder, transformer and heavy-load low voltage distribution switchgear panels. It delivers reliable voltage and current signal acquisition and multi-protection logic calculation, stable circuit breaker trip control output and fault event recording judgment, and convenient breaker replacement for ABB low-voltage intelligent power distribution systems.
Features ABB EMAX2 E1.2B supports comprehensive adjustable protection curves and high-precision power measurement, smart grid communication integration for remote supervision and power management. Galvanic isolation separates CT/PT signal circuit from trip control and communication circuit to suppress surge and electromagnetic interference, standard EMAX2 switchgear layout supports hot-swap maintenance requirement for withdrawable type. The breaker maintains consistent voltage and current signal acquisition and multi-protection logic calculation and accurate circuit breaker trip control output and fault event recording judgment under continuous power grid operation.
Technical Parameters ABB SACE EMAX2 E1.2B complies with CE low voltage power distribution standards, supporting sustained voltage and current signal acquisition and multi-protection logic calculation, real-time circuit breaker trip control output and fault event recording judgment and straightforward breaker replacement during distribution cabinet overhaul and commissioning.
Working Principle Three-phase mains current passes through current transformer and voltage transformer into ABB EMAX2 E1.2B air circuit breaker. The trip unit converts analog signals into digital values and executes overload, short-circuit and earth fault discrimination; when fault condition reaches trip threshold, the breaker outputs trip command to cut off power circuit, meanwhile captures fault waveform and electrical parameter data for post-fault analysis. When signal conditioning, trip unit or auxiliary control circuit ages and fails, technicians cut off upstream power supply and carry out breaker replacement to resume normal voltage and current signal acquisition and multi-protection logic calculation and circuit breaker trip control output and fault event recording judgment.
Application Fields ABB SACE EMAX2 E1.2B is widely used in industrial plant, data center, commercial building, power plant auxiliary and renewable energy station low voltage main distribution panels. It undertakes main protection and load break tasks for intelligent low voltage power distribution systems. This ABB EMAX2 intelligent air circuit breaker ensures dependable voltage and current signal acquisition and multi-protection logic calculation, stable circuit breaker trip control output and fault event recording judgment and easy breaker replacement for power distribution renovation and EMAX2 spare part stocking projects.