ALSTOM KBCH 13001P15MEL Transformer Differential Protection Relay Description
Description
ALSTOM KBCH 13001P15MEL Transformer Differential Protection Relay Description
Overview
The ALSTOM KBCH 13001P15MEL is a high-performance transformer differential protection relay designed for power transformer main protection. This transformer differential protection relay detects internal faults inside power transformers, and the transformer differential protection relay restrains inrush current and external fault current to avoid false tripping. It adopts classic electromagnetic differential principle, supports panel mounting and is widely used as spare protective component for old power station and substation equipment overhaul.
Features
The ALSTOM KBCH 13001P15MEL provides stable differential current detection for transformer winding short circuit and turn-to-turn fault. The differential current detection uses built-in inrush restraint circuit to block action during transformer energization, and the differential current detection matches different transformer wiring groups and CT ratio settings. It has independent trip contact and alarm contact, with front indicator to display operating and trip status. It can cooperate with overcurrent backup protection, and the setting parameters are adjusted by internal tap position. The robust metal shell resists vibration and electromagnetic interference in high-voltage switchgear cabinets.
Technical Parameters
The ALSTOM KBCH 13001P15MEL is designed for 5A CT secondary circuit, compatible with 50Hz and 60Hz power systems. Its auxiliary supply supports common AC and DC rated voltage options. The working temperature ranges from -25℃ to +70℃, non-condensing humidity 5% to 95%. It complies with power industry relay standards and adopts standard panel cutout size for direct replacement of old KBCH series relays.
Working Principle
The ALSTOM KBCH 13001P15MEL collects current signals from the primary side and secondary side current transformers of the transformer. The relay calculates the difference between the two groups of current. The whole protection operation relies on accurate fault discrimination, and the fault discrimination distinguishes internal short-circuit fault from normal excitation inrush and external through fault. Reliable fault discrimination sends trip signal to the circuit breaker quickly to cut off the faulty transformer and prevent accident expansion.
Application Fields
The ALSTOM KBCH 13001P15MEL is widely used in thermal power, hydro power and industrial substation systems. It serves as the main differential protection for distribution transformers and medium-voltage power transformers.