ABB 3AXD50000038423 (AFIN-02C)motor control board engineered
Description
Product Introduction
Model Interpretation
3AXD50000038423: Official ABB part number for order and inventory management.
AFIN‑02C: Product model, representing an advanced motor interface board with insulation monitoring capability.
The suffix “C” indicates a revised version, optimized for compatibility with modern ABB drive platforms.
Technical Parameters
Operating Voltage: 24 V DC ±15%
Test Voltage: 500 V DC (for insulation measurement)
Measurement Range: 0.1 MΩ to 1000 MΩ
Accuracy: ±5% of reading
Operating Temperature: −25 °C to +70 °C
Storage Temperature: −40 °C to +85 °C
Protection Class: IP20
Dimensions: 142 mm × 100 mm × 38 mm
Weight: 0.15 kg
Origin: Sweden
Interface and Communication Configuration
Power Interface: 24 V DC screw terminals for stable power supply.
Measurement Interface: Dedicated high‑voltage terminals for connecting motor windings and cables.
Signal Output: Relay contacts for alarm and fault signaling.
Communication: RS‑485 interface for data exchange and remote monitoring.
Status Indicators: Multi‑color LEDs display power, measurement, and fault status in real time.
Core Functions
Insulation Resistance Monitoring: Continuously measures phase‑to‑ground insulation resistance of motor windings and cables.
Early Warning: Triggers an alarm when resistance drops below a user‑configurable threshold.
Fault Protection: Sends interlock signals to shut down the drive in the event of severe insulation failure, preventing electric shock and equipment damage.
Offline Testing: Supports 500 V DC offline insulation tests for periodic maintenance.
Signal Conditioning: Processes motor‑side signals and transmits control commands between the drive and motor.
Application Scenarios
Compatible Drives: ABB ACS580, ACS880, and ACQ580 series low‑voltage AC drives.
Industries: Water and wastewater treatment, oil and gas, chemical, mining, food and beverage, and general manufacturing.
Equipment: Pumps, fans, compressors, conveyors, and other critical motor‑driven machinery requiring high reliability.
Operation and Maintenance Instructions
Installation: Mount on a DIN rail or panel inside the control cabinet. Use shielded cables and separate high‑voltage measurement wires from control cables to avoid interference.
Routine Check: Regularly inspect LED status and terminal tightness. Clean dust with a dry cloth.
Calibration: Perform professional calibration annually to ensure measurement accuracy.
Replacement: Supports hot swapping; replace directly without shutting down the system.
Safety: Disconnect all power before disassembly to ensure personal and equipment safety.
Get a Quote