ABB 5SGY55L4500(5SHY55L4500) high‑power asymmetric Integrated Gate‑Commutated Thyristor (IGCT) module
Description
Product Introduction
Model Interpretation
5S: ABB high‑power semiconductor series
GY: Asymmetric IGCT, unidirectional switching
55: 5500 A class current rating
L: Low‑loss version
4500: 4500 V repetitive peak blocking voltage
This is a high‑current, medium‑frequency optimized base variant.
Technical Parameters
Repetitive peak blocking voltage (VDRM): 4500 V
Max continuous on‑state current (ITGQM): 5000 A
Peak surge current (ITSM): 33 kA
Typical on‑state voltage drop (VT0): 1.22 V
On‑state resistance (rT): 0.28 mΩ
Max switching frequency: up to 1000 Hz (medium‑frequency optimized)
Operating junction temperature: −40 °C to +125 °C
Storage temperature: −40 °C to +85 °C
Cooling: deionized water cooled baseplate
AC insulation (main terminals): 12 kV
Mounting force: 36–44 kN
Weight: approx. 4.2 kg
Interface and Communication Configuration
Integrated gate drive with fiber‑optic control interface, providing high EMI immunity
Main power terminals: large copper busbars for low‑resistance, high‑current connections
Water‑cooled baseplate for efficient heat dissipation
Built‑in temperature and current sensors for real‑time monitoring and fault diagnostics
Status feedback via fiber optics for system control and protection
Core Functions
Delivers stable 4500 V / 5000 A high‑power switching for medium‑voltage conversion systems
Ultra‑low conduction and switching losses improve system energy efficiency
Snubberless fast turn‑off capability simplifies peripheral circuit design
Rugged press‑pack structure ensures long‑term stability under harsh industrial conditions
Optimized for medium frequencies (<1 kHz), ideal for high‑power, dynamic applications
Application Scenarios
Medium‑voltage drives (e.g., ABB ACS6000 series)
Static Var Compensators (SVC) and STATCOM for grid power quality control
Wind turbine converters and high‑power PV inverters
HVDC Light transmission systems
Heavy industries: power generation, metallurgy, mining, oil and gas
Operation and Maintenance Instructions
Mount the module on a water‑cooled heat sink with clamping force 36–44 kN
Connect main terminals with professional high‑current busbars; use dedicated fiber cables for gate signals
Maintain cooling system with qualified deionized water, stable flow and pressure
Inspect appearance, connections and cooling performance quarterly
Before disassembly/replacement: fully de‑energize and discharge residual voltage
Handle with anti‑static protection to avoid ESD damage
Get a Quote