SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P Air Circuit Breaker Description
Description
SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P Air Circuit Breaker Description
Overview
The SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P is a heavy-duty air circuit breaker designed for low-voltage power distribution systems. This air circuit breaker delivers reliable protection for main feeders and distribution cabinets, and the air circuit breaker supports stable isolation and fault interruption under high load conditions. It adopts modular drawout or fixed structure, compatible with MicroLogic trip units for flexible protection configuration in industrial and commercial power networks.
Features
The SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P offers comprehensive power protection including overload, short-circuit, earth fault and phase imbalance functions. The power protection settings can be adjusted locally or via communication modules, and the power protection logic supports selective coordination to limit fault impact range. It has visible contact position indication, mechanical interlock and anti-misoperation design. It supports standard Modbus communication for remote status monitoring, and complies with IEC 60947-2 standard for power isolation. Maintenance and replacement can be finished quickly for drawout version without full power cut.
Technical Parameters
The SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P has rated current 800A, 3-pole design, rated operational voltage 1000V and short-circuit breaking capacity 12kA. It works for 50Hz / 60Hz AC system, ambient temperature range from -25℃ to +70℃. It supports external auxiliary contacts, shunt release and undervoltage release. The trip unit can be upgraded on site, and fault event logs are stored for troubleshooting.
Working Principle
Under normal operation, the SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P keeps the main contacts closed to transmit load current. When abnormal current occurs, the trip unit detects signals and sends a trigger command to open internal contacts rapidly. The whole protection loop relies on accurate current sensing, and the current sensing module continuously samples three-phase current data. High-precision current sensing ensures fast response to short-circuit and overload events to avoid equipment burnout.
Application Fields
The SCHNEIDER MASTERPACT NW08H1 800A 1000V 12kA 3P is widely used in power plants, data centers, chemical plants, metallurgy and building distribution systems. It is used as incoming breaker, bus tie breaker and outgoing feeder breaker for critical power loads.