SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 Air Circuit Breaker Description
Description
SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 Air Circuit Breaker Description
Overview
The SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 is a high-performance air circuit breaker belonging to the MasterPact NW series for critical low voltage distribution systems. This air circuit breaker serves as main incoming, bus tie and feeder protection device, and the air circuit breaker integrates switching, protection, measurement and communication functions into one compact withdrawable unit. It adopts robust mechanical structure and supports matched intelligent trip units for selective coordination in industrial power distribution cabinets.
Features
The SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 provides configurable selective protection for overload, short time and short circuit faults. The selective protection curve can be adjusted to coordinate with downstream protective devices, and the selective protection limits the affected area when electrical fault occurs. It supports withdrawable rack installation for easy inspection, testing and replacement without cutting off upstream power completely. Built-in measurement function records power, energy and event data, and optional communication module enables remote monitoring and fault record upload. Mechanical and electrical status indicators show breaker position, closing and trip status clearly. It carries anti-arc safety design and meets strict industrial certification requirements for heavy load environments.
Technical Parameters
The SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 has rated current 800A, rated impulse withstand voltage 12kV, compatible with 50Hz and 60Hz three-phase AC distribution systems. Its working temperature ranges from -25℃ to +70℃, non-condensing humidity 5% to 95%. It supports 3-pole and 4-pole configuration, and matches Ekip series trip units with LSIG function. It complies with IEC 60947-2 standard and adopts drawout base for cabinet mounting.
Working Principle
Current signals from the distribution line are transmitted to the SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 and detected by built-in sensors. The matched trip unit judges whether the current exceeds preset protection thresholds. The whole protection response relies on accurate fault detection, and the fault detection distinguishes overload, short circuit and earth fault types. Reliable fault detection sends trip command rapidly to open the main contacts and isolate the faulty circuit to protect transformers, cables and important loads.
Application Fields
The SCHNEIDER NW08 HA 12KV 800A 1-CE661A02 is widely used in data centers, petrochemical plants, power stations, metallurgy and large manufacturing workshops. It is applied for main power incoming cabinet, bus tie cabinet and important load feeder control.