PROSOFT MVI71-MNET 800mA Modbus TCP/IP Communication Module Description
Description
PROSOFT MVI71-MNET 800mA Modbus TCP/IP Communication Module Description
Overview
The PROSOFT MVI71-MNET is a single-slot Modbus TCP/IP communication module designed for Rockwell PLC-5 control systems. This Modbus TCP/IP communication module serves as a bridge between the PLC backplane and Modbus TCP network devices, and the Modbus TCP/IP communication module supports both client and server mode for bidirectional register data exchange. It requires 800mA backplane current draw at 5Vdc, widely used for PLC-5 system networking upgrade, equipment retrofit and communication replacement.
Features
The PROSOFT MVI71-MNET provides reliable data exchange between PLC processor and Modbus TCP instruments, controllers and meters. The data exchange supports Enron and Daniel floating-point data format conversion, and the data exchange manages up to ten concurrent Modbus TCP server connections on port 502. It has a 5000-word shared register database for data buffering, and supports configurable message timeout, parity check and communication fault monitoring. The 10/100BASE-T Ethernet interface adopts isolated circuit design to suppress surge and noise interference from field networks. The configuration port connects to PC for parameter setup, diagnostic viewing and firmware update. It supports ladder logic driven BTR/BTW data transfer with the PLC CPU, and front LED indicators clearly show network, power and fault status. The compact 1771 chassis form factor fits inside PLC cabinet rack without extra space modification.
Technical Parameters
The PROSOFT MVI71-MNET operates on 5V backplane power supply with 800mA current consumption. Its working temperature ranges from 0℃ to 60℃, non-condensing humidity 5% to 95%. It complies with industrial EMC anti-interference and Class I Division 2 hazardous location certification. It supports standard Modbus function codes and flexible register mapping arrangement, and the built-in non-volatile memory retains network configuration after power off. It matches the dedicated configuration software for project download and troubleshooting.
Working Principle
Data from the PLC processor is transmitted to the PROSOFT MVI71-MNET via PLC backplane bus and stored in the shared register memory. The onboard processor packages or parses Modbus TCP frames and exchanges data with remote Modbus TCP devices through Ethernet. The whole communication loop relies on stable protocol conversion, and the protocol conversion translates PLC backplane data format into standard Modbus TCP message frames. Reliable protocol conversion realizes transparent data interaction between Rockwell control system and third-party process equipment.
Application Fields
The PROSOFT MVI71-MNET is widely used in water treatment, power plants, petrochemical, oil & gas and pulp & paper industries. It is applied for PLC-5 system Modbus TCP networking, instrument data collection and multi-controller interconnection schemes.