PROSOFT MVI56-MCMRCC Modbus Communication Module Description
Description
PROSOFT MVI56-MCMRCC Modbus Communication Module Description
Overview
The PROSOFT MVI56-MCMRCC is a ControlLogix chassis single-slot Modbus communication module (reduced data block version) for Rockix ControlLogix control systems. This Modbus communication module provides dual isolated serial ports supporting Modbus RTU/ASCII master and slave mixed operation, and the Modbus communication module acts as protocol gateway between ControlLogix backplane and serial Modbus field instruments, drives and meters. It uses the compact reduced I/O data block design which is suitable for ControlNet remote rack applications to save backplane bandwidth occupation, widely used for PLC system upgrade, old MVI56-MCM spare replacement and field retrofit.
Features
The PROSOFT MVI56-MCMRCC delivers stable serial data exchange between ControlLogix CPU and Modbus serial devices. The serial data exchange supports independent master/slave configuration for each channel, and the serial data exchange shares a common register database up to 5000 words. It supports floating-point register mapping for 32-bit float data reading and writing, and carries built-in communication watchdog and line fault monitoring function. The front alphanumeric scrolling display shows module fault code, port status and communication count directly for on-site troubleshooting. It supports RIUP hot swap function, so it can be replaced without shutting down the whole rack under the allowed scheme. The configuration software sets Modbus command table, timeout and parity parameters, and the diagnostic tool monitors communication traffic in real time. The isolated RS485/RS232 circuit suppresses surge and noise interference from long cable wiring.
Technical Parameters
The PROSOFT MVI56-MCMRCC is powered from ControlLogix backplane 5Vdc, consumes 800mA backplane current. Its working temperature ranges from 0℃ to 60℃, non-condensing humidity 5% to 95%. It complies with Rockwell ControlLogix backplane specification and industrial EMC anti-interference standard. Two serial ports support baud rate from 1200bps up to 115200bps software configuration, and the terminal block wiring layout is convenient for field cable arrangement.
Working Principle
Register data from the ControlLogix processor is transmitted to the PROSOFT MVI56-MCMRCC through backplane bus. The onboard processor converts data into Modbus RTU/ASCII frame and sends out via serial port. When response data returns from field Modbus devices, the module parses message and writes back to the shared register area. The whole communication loop relies on reliable protocol conversion, and the protocol conversion establishes transparent bidirectional data interaction between PLC and third-party process equipment. Reliable protocol conversion realizes stable monitoring and closed-loop signal interaction for pressure, flow and temperature control loops.
Application Fields
The PROSOFT MVI56-MCMRCC is widely used in water treatment, power plant, petrochemical and oil & gas industries. It is applied for Modbus instrument data collection, flow meter communication and valve position signal acquisition in ControlLogix control schemes.
Get a Quote