Schneider Electric 490NAD91105 Profibus DP Connector
May 30, 2026

Schneider Electric 490NAD91105 Profibus DP Connector

Product Description The 490NAD91105 is a right‑angle 9‑pin SUB‑D Profibus DP connector with an integrated programming port, designed for middle nodes in a Profibus DP network. It supports daisy‑chain wiring (one cable in, one cable out) while providing a dedicated port for on‑site programming and diagnostics without disconnecting the bus.

Description

Model Definition

  • 490: Modicon network accessory series

  • NAD: Profibus DP connector category

  • 91105: In‑line connector with programming port, no terminator

Technical Specifications

Hardware & Interface
  • Protocol: Profibus DP (RS‑485, galvanic isolation)

  • Connector: 9‑pin male SUB‑D (device side), right‑angle

  • Programming Port: 9‑pin female SUB‑D (front, for PLC/device programming)

  • Termination: None (for middle nodes only)

  • Wiring: Screw terminals for IN/OUT bus cables

  • Cable Entry: Side entry

  • Color: Violet

  • Dimensions: ~30 mm (H) × 55 mm (W) × 65 mm (L)

  • Weight: ~50 g

  • Pinout: Pins 3 (RxD/TxD‑N), 5 (DGND), 6 (VP), 8 (RxD/TxD‑P)

Performance & Environmental
  • Data Rate: 9.6 kbps – 12 Mbps

  • Max Nodes/Segment: 32 (127 with repeaters)

  • Operating Temp: 0 °C to +60 °C

  • Storage Temp: −25 °C to +80 °C

  • Humidity: 5%–95%, non‑condensing

  • Protection: IP20

Core Functions

  • In‑Line Connection: Passes Profibus DP signals through for daisy‑chain topology

  • Integrated Programming Port: Enables direct connection to a PC for programming, monitoring, and diagnostics without breaking the bus

  • No Termination: Reserves termination for bus ends (use 490NAD91103 there)

  • Signal Integrity: Complies with Profibus DP electrical standards for reliable communication

Application Scenarios

  • Middle stations in Profibus DP networks (PLCs, drives, I/O)

  • Modicon M340/Momentum/Premium PLCs

  • ATV61/ATV71 series VFDs with DP communication cards

  • Lexium 15 motion systems, TeSys motor starters, Preventa Safety PLCs

  • On‑site maintenance: Quick programming access without rewiring

Usage & Maintenance

  • Use only for intermediate nodes (not at bus start/end)

  • Wire incoming bus cable to “IN,” outgoing to “OUT”

  • Use 490NAD91103 (with terminator) at the first and last nodes

  • Keep connections tight and dry; inspect periodically for corrosion

  • For programming, connect PC directly to the front 9‑pin female port

490NAD91103 / 91104 / 91105 Comparison

ModelTerminatorProgramming PortBest For
490NAD91103✅ 120ΩBus end nodes
490NAD91104Bus middle nodes (standard)
490NAD91105Bus middle nodes (with programming access)


Get a Quote